UPS: POWER SUPPLY ANALYSIS & TROUBLESHOOTING
ACARA
25 – 26 Agustus 2018 | Rp 6.900.000,- per peserta di Hotel Ibis, Yogyakarta
01 – 02 September 2018 | Rp 6.900.000,- per peserta di Hotel Ibis, Yogyakarta
08 – 09 September 2018 | Rp 6.900.000,- per peserta di Hotel Ibis, Yogyakarta
15 – 16 September 2018 | Rp 6.900.000,- per peserta di Hotel Ibis, Yogyakarta
Description
This technical course begins with a discussion of the need for UPS systems. It then covers the relative comparisons between various UPS topologies and their modes of operation. The batteries used for UPS systems are covered next. How a battery works, their maintenance, safety and testing is throughly discussed.
A solid working knowledge of the typical electrical components found within a UPS is developed before exploring how AC is converted to DC and then inverting DC back to AC. When all of the above elements of a UPS are understood, a theoretical rectifier and inverter feedback loop are throughly discussed. This will be followed by a trouble shooting exercise. Students are given failure scenarios where they work in groups to find which circuit component has opened, shorted or significantly changed in value to produce the alarm condition described. The course finishes with a general discussion on UPS system trouble shooting.
Some working knowledge of basic electrical engineering principles is required, although this will be revised at the beginning of the course. Real-life experience in working with batteries and UPS systems will enable the workshop to be placed in context.
Training Outline UPS Systems
- Introduction to UPS Systems
- Power conditioners
- Uninterruptible power systems
- Power quality source alternatives
- Power disturbance cost comparisons
- Three General Types of UPS’s Kinetic (Motor Generator Sets)
- Flywheel
- Static and Components
- Rectifier
- Batteries
- Inverter
- Three types of Static UPS’s
- Traditional UPS
- Static UPS
- Static UPS with Bypass
- UPS Operation Overview
- The Need for UPS System
- Power System Disturbances
- Basic Type of UPS Systems
- Introduction to Batteries
- Primary Batteries
- Secondary Batteries
- Lead Acid Batteries
- Nickel Cadmium Batteries
- Semiconductors
- Diodes
- SCR’s
- Transistors
- AC to DC Conversion
- Full Bridge
- Three Phase
- Six Pulse
- DC to AC Inversion
- Quasi Square wave
- PWM waveform
- UPS System Overview
- Rectifier Stage
- Inverter Stage
- UPS System Troubleshooting
- Basic Use of Test Equipment
- Rectifier Troubleshooting
- Inverter Troubleshooting
COURSE METHODE
- Lecture
- Discussion
- Simulation
- Animation
- Video
- Software
- Virtual Laboratory
Hotel Ibis Malioboro ,Yogjakarta
- 25 – 26 Agustus 2018
- 01 – 02 September 2018
- 08 – 09 September 2018
- 15 – 16 September 2018
- 22 – 23 September 2018
- 29 – 30 September 2018
- 06 – 07 Oktober 2018
- 13 – 14 Oktober 2018
- 20 – 21 Oktober 2018
- 27 – 28 Oktober 2018
- 03 – 04 November 2018
- 10 – 11 November 2018
- 17 – 18 November 2018
- 24 – 25 November 2018
- 01 – 02 Desember 2018
- 08 – 09 Desember 2018
- 15 – 16 Desember 2018
- 22 – 23 Desember 2018
- 29 – 30 Desember 2018
Investasi dan Fasilitas
- Rp. 6.900.000 (Non Residential, Belum Termasuk Pajak)
- VIP training Rp 8.900.000 (4 Hari , Non Residential dengan tambahan Fasilitas Paket studi lapangan/ City tour dan Belum Termasuk Pajak)
- Quota minimum 2 peserta
- Fasilitas : Certificate,Training kits, USB,Lunch,Coffe Break, Souvenir
- Untuk peserta luar kota disediakan transportasi antar-jemput dari Bandara/Stasiun ke Hotel khusus bagi perusahaan yang mengirimkan minimal 3 orang peserta)
Instructure
Tugino, ST MT & Team
UNINTERRUPTIBLE POWER SUPPLY (UPS) POWER SUPPLY ANALYSIS & TROUBLESHOOTING